Skip to main content
AgriSpectra-Q
FROZEN SCIENTIFIC BENCHMARK

Research & Evidence

Scientific protocol, validation evidence, and current limitations of the AgriSpectra-Q industrial PoC. All results are frozen — no live run affects these figures.

What Evidence Exists

3 EnMAP scenes
UAE & Gulf region — real EO data, no simulation
224 spectral bands
Full hyperspectral L2A sensor output per scene
5 random seeds
Seeds 11, 22, 33, 44, 55 — statistical stability
Spatially separated
Train/validation/test splits prevent leakage
90 total runs
6 models × 3 scenes × 5 seeds
10,000 bootstrap reps
Paired bootstrap for significance testing

Key Numerical Results

Mean F196.40%Highest among six evaluated systems
PR-AUC99.47%Precision-recall area under curve
ROC-AUC99.87%Discrimination performance
Calibrated ECE0.73%After post-hoc scaling — well-calibrated
Inspection recall~49%At 10% budget — ~5× better than random
Bootstrap CI vs HSI-RF[−0.0012, +0.0027]Crosses zero — superiority not established

Eight-Step Scientific Protocol

1

Scene preparation

Three real EnMAP L2A GeoTIFF scenes. Windowed streaming with constant memory footprint. NoData masking.

2

Spectral anomaly proxy

RMS standardised deviation over 32 evenly-spaced bands. Scene-relative percentile thresholds (P50/P80/P95). Unsupervised — no disease labels.

3

Spatial evaluation splits

Spatially separated train/validation/test split per scene. No pixel-level leakage between splits.

4

Five random seeds

Seeds 11, 22, 33, 44, 55 per model per scene. 90 total evaluation runs. Mean and std computed per metric.

5

Frozen test predictions

Test-set predictions locked before analysis. No post-hoc adjustment of thresholds or model parameters.

6

Paired bootstrap

n = 10,000 replicates. 95% confidence interval for pairwise difference vs HSI-RF. CI reported verbatim.

7

Calibration

Post-hoc Platt scaling. Expected Calibration Error (ECE) reported before and after calibration.

8

Ablation study

Quantum-inspired component isolated. Measurable contribution confirmed on Scene 01. Not a quantum hardware claim.

What This PoC Does Not Provide

No field validation — no field-labelled disease or pest target exists.

No blind fourth EnMAP scene — all scenes were used during development.

No complete six-model LOSO evaluation — leave-one-scene-out not yet verified.

Benchmark target is a Spectral Anomaly Proxy — not an independently labelled biological outcome.

No proven quantum advantage — the quantum-inspired layer provides measurable contribution but no quantum hardware was used.

No measured financial ROI — inspection cost savings are not verified against operational baselines.

Wavelength metadata unavailable in GeoTIFF — band indices reported, physical wavelengths not verified.

Priority thresholds are scene-relative percentiles — not absolute disease severity levels.

Processing time varies per scene — not suitable for real-time operational use without further optimisation.

The current PoC has no field validation, no field-labelled disease or pest target, no blind fourth scene, no complete six-model LOSO evaluation, no proven quantum advantage, and no measured financial ROI. All priority zones require independent field verification.